725 x 420 x 288mm.

20kW and 24kW

Button Control Panel

52dB

High Savings with 1/7 Modulation

High efficiency up to 97.5%
In addition to their compact and beautiful appearance, Ewa combi boilers provide both economical and safe combustion thanks to their "Smart Gas" technology.
- Premix Stainless steel heat exchanger with high efficiency and long life
- Continuous hot water with pre-heat
- 3 year warranty
- Specially designed Metal Front Surface
- Compliant with EU ErP Regulation
- Hot Water Comfort in Double Tap
- Lowest NOx value in exhaust gas (in Class 6)
- Quiet Operation and Low Heat Loss with Insulated Body
- DG and LPG Compatible combi boiler (no need to change parts for LPG)
- Erp Compatible Frequency Controlled Pump
TECHNICAL DATA | UNIT | Ewa 20 | Ewa 24 | ||||||
Gas Circuit | DG | DG | LPG | LPG | DG | DG | LPG | LPG | |
Gas Type | G20 | G25 | G30 | G31 | G20 | G25 | G30 | G31 | |
Gas Supply Pressure | 20 | 25 | 30 | 37 | 20 | 25 | 30 | 37 | |
Maximum Gas Consumption | m³/h | 2.12 | 2.58 | 0.708 | 0.81 | 2.38 | 2.85 | 0.73 | 0.92 |
Minimum Gas Consumption | m³/h | 0.36 | 0.42 | 0.13 | 0.14 | 0.37 | 0.43 | 0.11 | 0.11 |
Seasonal Space Heating Energy Class | A | ||||||||
Seasonal Space Heating Energy Efficiency (ηs) | % | 91.2 | 91.2 | 90.5 | 90.5 | 92 | 92 | 92 | 92 |
Useful Efficiency at Nominal Heat Power and High Temperature Regime(2) (η4) | % | 87.6 | 87.6 | 88.3 | 88.3 | 87.6 | 87.6 | 87.6 | 87.6 |
Useful Efficiency (1) (η1) at 30% of Nominal Heat Power and Low Temperature Regime (Partial Load) | % | 96.4 | 96.4 | 95.5 | 95.5 | 97.5 | 97.5 | 97.5 | 97.5 |
Heating Circuit | G20 | G25 | G30 | G31 | G20 | G25 | G30 | G31 | |
Maximum Heat Load Qn | kW | 20 | 20 | 20 | 20 | 24.25 | 24.25 | 24.25 | 24.25 |
Minimum Heat Load Qn | kW | 3.5 | 3.5 | 3.5 | 3.5 | 3.5 | 3.5 | 3.5 | 2.8 |
Maximum Heat Power Pn (50/30 °C) | kW | 21.1 | 21.1 | 20.7 | 20.7 | 25 | 25 | 24.7 | 25 |
Minimum Heat Power Pn (50/30 °C) | kW | 3.7 | 3.7 | 3.6 | 3.6 | 3.6 | 3.6 | 3.55 | 2.9 |
Maximum Heat Power (P4) (80/60 °C) | kW | 19.4 | 19.4 | 19.4 | 19.4 | 23.7 | 23.7 | 23.6 | 23.7 |
Minimum Heat Power (P4) (80/60 °C) | kW | 3.4 | 3.4 | 3.3 | 3.3 | 3.0 | 3.0 | 3.2 | 2.5 |
Temperature Setting Range (Minimum/Maximum) High/Low | °C | 25 ÷ 80/25 ÷ 47 | |||||||
Working Pressure (Maximum/Minimum) | bar | 3/0.5 | |||||||
Expansion Tank Volume | bar | 7/8 | |||||||
Pump Pressure (at constant flow) | mSS | 6.2 (700 l/h) | |||||||
Maximum Pump Pressure (Q = 0 m³/h) | mH2O | 6.2 | |||||||
Maximum Pump Flow | m³/h | 2.3 | |||||||
Pump Energy Efficiency Index | EEI | £0.20 | |||||||
Hot Water Energy Efficiency Class/Declared Load Profile | A/XL | A/L | A/XL | ||||||
Water Heating Energy Efficiency | % | 85 | 81 | 84 | |||||
Maximum Gas Consumption | m³/h | 2.47 | 2.83 | 0.73 | 0.94 | ||||
Hot Water Modulation Rate | % | 15/100 | 14/100 | ||||||
Hot Water Circuit (Maximum) Heat Load | kW | 23.7 | 23.7 | 23.7 | 23.2 | 25.8 | |||
Hot Water Circuit (Minimum) Heat Load | kW | 3.5 | 3.5 | 3.5 | 3.5 | 3.5 | |||
Hot Water Flow Rate Minimum/Maximum (Δt: 30 °C/Δt: 35 °C) | l/min | 1.5/(11/10) | 1.5/(12/11) | ||||||
Domestic Water Pressure (Minimum/Maximum) | bar | 0.5/10 | |||||||
Temperature Setting Range (Min - Max) | °C | 35 - 60 | |||||||
Electrical Circuit Protection Index | ROPE | IPX5D | |||||||
Electricity Consumption (Min./Max.) [Supply: 230 V +%10; -%15] | Watt | 57/86 | 55/95 | ||||||
Waste Gas Circuit | G20 | G25 | G30 | G31 | G20 | G25 | G30 | G31 | |
(80/60 °C) Exhaust Gas Temperature (Minimum/Maximum) | °C | 55/78 | 55/78 | 54/77.8 | 54/78 | 69/71 | 65/70 | 57/70 | 60/70 |
(50/30 °C) Exhaust Gas Temperature (Minimum/Maximum) | °C | 37/57 | 37/57 | 41/55 | 41/55 | 49/51 | 48/49 | 43/57 | 47/51 |
Maximum Flue Gas Temperature [Maximum Hot Water Mode] | °C | 78 | 70 | ||||||
NOx Weight (NOx Class: 6) | mg/kWh | 33 | 33 | 38 | 38 | 20 | 19 | 42 | 31 |
General/Dimensions (H x W x D) mm | 725x420x288 | ||||||||
Sound Level | dB(A) | 52 | |||||||
Maximum Chimney Distance (Horizontal)*/(Vertical)* | m | 10/11 | |||||||
Net/Packaged Device Weight | kg | 30/31.8 | 32.6/33.8 | ||||||
Chimney Connection Types | B23, B23P, B33, B33P, B53, B53P, C13, C33, C43, C53, C63, C83, C93, C(10)3 | ||||||||
(1) For condensing combination heaters; Low temperature means 30 °C, for low temperature boilers 37 °C and for other heaters 50 °C return temperature (at the heater inlet). (2) High temperature regime means a return water temperature of 60 °C at the heater inlet and an outlet water temperature of 80 °C. * In the maximum chimney distance, the chimney length must be reduced by 1 metre for every 90° bend and 0.5 metre for every 45° bend. |